# How to Read a Cyclic Voltammogram with the Free MolDraw CV Viewer

Published: 15 Oct 2026 · Author: Scidart Academy · Reading time: ~6 min

![Reversible cyclic voltammogram with the anodic peak Epa, the cathodic peak Epc and the half-wave potential E½ marked](https://www.moldraw.com/blog/thumbs/cv-viewer-guide.webp)

A reversible cyclic voltammogram with Epa, Epc and E½ marked.

**Short answer:** Open the [cyclic voltammetry viewer](https://www.moldraw.com/tools/cv-viewer/index.html), press **Open CV file(s)** or drop a CSV, CH Instruments, BioLogic, Gamry or Autolab export onto the page. Pick a cycle and read Epa, Epc, E½, ΔEp and ipa/ipc, with a short note on what they mean. The same page converts reference electrodes, estimates HOMO and LUMO from onset potentials and runs a Randles–Ševčík scan-rate analysis. Your files stay on your device.

## Try the CV viewer here

Press **Ferrocene (reversible)** in the live viewer to load a worked example.

Click to load the live viewer in this page, or [open the full cyclic voltammetry viewer](https://www.moldraw.com/tools/cv-viewer/index.html). Your files stay on your device.

## Why use a browser CV viewer?

Potentiostat software usually runs on one lab computer and reads one vendor's files, so collaborators often cannot open your data. Reading peaks by hand from a plot is slow and error-prone. The MolDraw viewer reads the common exports, overlays them and measures the standard values the same way every time.

## Cyclic voltammetry in brief

The working electrode potential is swept linearly to a vertex and back while the current is recorded. The **anodic peak** (Epa, current ipa) comes from oxidation. The **cathodic peak** (Epc, current ipc) comes from reduction.

For an electrochemically reversible couple, **E½ = (Epa + Epc)/2** is close to the formal potential. The peak separation **ΔEp** is about 59/n mV at 25 °C, where n is the number of electrons, and it does not change with scan rate. A ratio **ipa/ipc** near 1 means both forms are stable during the scan. A wider ΔEp points to slower electron transfer or uncompensated resistance. A missing return peak means the product reacts away.

A potential only has meaning against a **reference electrode**. Aqueous work often uses SCE or Ag/AgCl. In organic solvents, IUPAC recommends reporting potentials against the ferrocene/ferrocenium couple (Fc/Fc+) measured in the same cell.

For organic semiconductors, the **onset** potentials of oxidation and reduction vs Fc/Fc+ give rough frontier orbital energies: E(HOMO) ≈ −(Eox, onset + 4.8) eV, and the same with the reduction onset for LUMO. The 4.8 eV value is a convention, not a constant.

The **Randles–Ševčík** equation links peak current to scan rate. For a reversible wave of a dissolved species at 25 °C, ip = 2.69 × 10⁵ n3/2 A D1/2 C v1/2. So ip grows with √v. For a species fixed on the electrode, ip grows with v instead.

## Files the viewer opens

| CSV or TXT | Potential and current columns, with optional time and cycle columns. Current units (A, mA, µA, nA) are read from the header. |
| --- | --- |
| Instrument exports | CH Instruments text exports, BioLogic EC-Lab .txt exports, Gamry .DTA files and Autolab NOVA ASCII exports. |
| Scan rate | Read from the header or a time column, or typed in mV/s next to the file name. |
| Cycles | Taken from a cycle column, or found from the turning points of the sweep. |

## How to analyse a CV step by step

1. Press **Open CV file(s)**, or drop files on the box. To explore first, press an example such as **Quasi-reversible** or **Irreversible oxidation**.
2. Under **Reference and units**, set **Data vs** to the electrode you measured against and **Show vs** to the one you want to report. If you ran ferrocene in the same cell, type its E½ in **Ferrocene E½ vs data ref (V)**.
3. Choose a cycle in the **Peaks** menu. Read the table and the "What it means" note under it.
4. For energy levels, open **HOMO / LUMO from onset potentials**. Tick **Use oxidation onset**, **Use reduction onset** or both, and **Mark onsets** to see them on the plot.
5. For a scan-rate series, select several files at once, or tick **Add to the plot instead of replacing**. Check each scan rate, open **Scan-rate analysis (Randles-Sevcik)**, and enter **Electrons n** and **Concentration (mM)**.
6. Save your work with **Export PNG**, **Export CSV** or **ip plot PNG**.

## What the viewer does

- **Overlays:** each file gets its own colour. Show, hide or remove files, and choose which cycles to draw.
- **Plain-language verdict:** the note calls ΔEp up to 75 mV reversible and up to 200 mV quasi-reversible. Peaks more than 0.8 V apart are treated as separate processes, so E½ and ΔEp are not given.
- **References and signs:** convert between SCE, two Ag/AgCl electrodes, SHE, NHE, Hg/HgO and Fc/Fc+. Oxidation is plotted up (IUPAC); tick **US convention** to flip it.
- **Scan-rate analysis:** ipa against √v with a fitted line and R², the slope of log ip against log v, a diffusion or surface verdict, and the diffusion coefficient D when n, area and concentration are set.
- **Current density:** set **Electrode area (cm²)** and tick **Current density** to plot j instead of I.

## Ways to use it in class and in the lab

- **Teaching reversibility:** load **Ferrocene (reversible)**, **Quasi-reversible** and **Irreversible oxidation** in turn and compare ΔEp, ipa/ipc and the return peak.
- **Reporting a new compound:** enter your ferrocene E½ and quote E½ vs Fc/Fc+, which other groups can compare directly.
- **Organic electronics:** estimate HOMO, LUMO and the electrochemical gap from a film CV, then compare the gap with the optical gap from the [UV-Vis spectrum viewer](https://www.moldraw.com/tools/uv-vis-viewer/index.html).
- **Mechanism checks:** run a scan-rate series to tell a diffusing species from one adsorbed on the electrode.

## Tips and limits

- Files rarely record the reference electrode, so check **Data vs** every time.
- The conversions use fixed aqueous values vs SHE. In organic solvents an internal ferrocene standard is more reliable.
- The scan-rate analysis uses the first cycle of each file. D assumes a reversible, diffusion-controlled wave at 25 °C.
- HOMO and LUMO values are estimates. Compare only values made with the same Fc/Fc+ level and the same method (onset or E½).
- With overlapping waves, check that the Epa and Epc markers sit on the peaks you mean.

The [tools page](https://www.moldraw.com/tools/) lists all the free MolDraw data viewers.

## Sources

- N. Elgrishi, K. J. Rountree, B. D. McCarthy, E. S. Rountree, T. T. Eisenhart, J. L. Dempsey, "A Practical Beginner’s Guide to Cyclic Voltammetry", *J. Chem. Educ.* 2018, 95, 197–206, [doi:10.1021/acs.jchemed.7b00361](https://doi.org/10.1021/acs.jchemed.7b00361)
- A. J. Bard, L. R. Faulkner, *Electrochemical Methods: Fundamentals and Applications*, 2nd ed., Wiley, 2001
- G. Gritzner, J. Kůta, "Recommendations on reporting electrode potentials in nonaqueous solvents", *Pure Appl. Chem.* 1984, 56, 461–466, [doi:10.1351/pac198456040461](https://doi.org/10.1351/pac198456040461)
- C. M. Cardona, W. Li, A. E. Kaifer, D. Stockdale, G. C. Bazan, "Electrochemical considerations for determining absolute frontier orbital energy levels of conjugated polymers for solar cell applications", *Adv. Mater.* 2011, 23, 2367–2371, [doi:10.1002/adma.201004554](https://doi.org/10.1002/adma.201004554)

## Questions and answers

### Why is my ΔEp larger than 59 mV for a couple that should be reversible?

Uncompensated resistance and slow electron transfer both widen ΔEp. Run ferrocene in the same cell. If it also shows a large ΔEp, the cell is the cause.

### Can I report potentials vs Fc/Fc+ if I measured against Ag/AgCl?

Yes. Set Data vs to your Ag/AgCl electrode, type the ferrocene E½ measured in the same cell, and set Show vs to Fc/Fc+. Without it, the viewer assumes +0.40 V vs SCE (acetonitrile), which is only approximate.

### How many files do I need for the scan-rate analysis?

At least three CVs at different scan rates. If a file does not give its scan rate, type it in mV/s next to the file name.

### Does the viewer handle files with several cycles?

Yes. Pick the cycle to analyse in the Peaks menu and tick which cycles to show on the plot.

## More MolDraw viewers and guides

[Cyclic voltammetry viewer](https://www.moldraw.com/tools/cv-viewer/index.html) [TGA and DSC viewer](https://www.moldraw.com/tools/tga-dsc-viewer/index.html) [UV-Vis viewer](https://www.moldraw.com/tools/uv-vis-viewer/index.html) [XPS viewer](https://www.moldraw.com/tools/xps-viewer/index.html) [Raman viewer](https://www.moldraw.com/tools/raman-viewer/index.html) [IR viewer](https://www.moldraw.com/tools/ir-viewer/index.html) [NMR viewer](https://www.moldraw.com/tools/nmr-viewer/index.html) [Mass spectrum viewer](https://www.moldraw.com/tools/mass-spec-viewer/index.html) [Protein viewer](https://www.moldraw.com/tools/protein-viewer/index.html) [TGA and DSC guide](https://www.moldraw.com/blog/tga-dsc-viewer-guide.html) [UV-Vis guide](https://www.moldraw.com/blog/uv-vis-spectrum-viewer-guide.html) [XPS peak fitting guide](https://www.moldraw.com/blog/xps-viewer-peak-fitting-guide.html) [Raman guide](https://www.moldraw.com/blog/raman-spectrum-viewer-guide.html) [IR guide](https://www.moldraw.com/blog/ir-spectrum-viewer-guide.html) [NMR guide](https://www.moldraw.com/blog/nmr-spectrum-viewer-guide.html) [Mass spectrum guide](https://www.moldraw.com/blog/mass-spectrum-viewer-guide.html) [Protein structure guide](https://www.moldraw.com/blog/protein-structure-viewer-guide.html) [Protein viewer plugin](https://www.moldraw.com/blog/protein-viewer-plugin-pdb-3d.html)

Last updated: October 15, 2026